AC to DC Single Output SMPS industrial power supply 12V16.7A 200W

Contact Now
HK Anenerge Co., Limited
City:shenzhen
Province/State:guangdong
Country/Region:china
Contact Person:MissSusie
Contact Now

AC to DC Single Output SMPS industrial power supply 12V16.7A 200W

Ask Latest Price
Video Channel
Place of Origin :China
Brand Name :Anenerge
Certification :CB UL cUL CE Rohs FCC
Packaging Details :White Box
Delivery Time :5-7 days
Payment Terms :T/T, Western Union
Supply Ability :50000 pcs per Month
MOQ :500 pcs
Contact Now

Add to Cart

Find Similar Videos
View Product Description
ModelSP-200-5SP-200-12SP-200-24SP-200-48
OutputDC voltage5V12V24V48V
Voltage tolerance±2%±2%±1%±1%
Rated current40A16.7A8.4A4.2A
Current range0-40A0-16.7A0-8.4A0-4.2A
Rated power200W200W200W200W
Ripple&noise100mvp-p100mvp-p150mvp-p2000mvp-p
DCvoltage ADJ.range-9%~+10%-9%~+10%±10%±10%
InputVoltage range90~264VAC,120~373VDC
frequency47~63HZ
AC current1.6A/115VAC,0.8A/230VAC
efficiency71%79%83%84%
Inrush currentCold start current 20A/115VAC,40A/230VAC
Leakage current< 3.5mA/240VAC
ProtectionoverloadRated output power115%~150% start over load protection
Protection type:cutoff output,auto recovery after fault condition is removed
Protection type:hiccup mode,auto-recovery after fault condition is removed
EnvironmentWorking temp,humidity-10℃~+60℃,20%~90%RH
Storagetemp,humidity-20℃~+85℃,10%~95%RH non-condensing
Withstand vibration10~500HZ,2G 10min/1cycle,period for 60 minutes,each axes
SafetyWithstand voltageI/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
Isolated resistanceI/P-O/P,I/P-FG,O/P-FG:100M ohms/500VDC
FitstandardSafety standardFit UL1012
EMC standardEN55022,CLASSA
OthersDimension199*99*50mm (L*W*H)
Note1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
Inquiry Cart 0